The reason for the dripping of the central air conditioning outlet


1, the material of the air outlet. The central air-conditioning air outlets are mainly made of wood materials, aluminum alloy materials and ABS materials. Due to the high cost performance and moderate price, many households use the air outlets of aluminum alloy materials, but it is necessary to pay attention to the cooling in the summer. The air supply temperature is too low, the construction heat preservation is not done well, the aluminum alloy material air outlet provided by the inferior manufacturer, the inferior manufacturer in order to save costs, the surface baking treatment is very casual, and even more than the market price of 5 dollars for self-sneeze treatment, then It is prone to condensation. The material selection is quite strict, the surface treatment of the tuyere is very detailed, and there are very strict requirements on the baking varnish. The baking varnish (note that this is baking varnish, not sneezing) must have a temperature of 180 degrees, completely fix the lacquer on the surface of the tuyere, and the surface lacquer The thickness needs to reach 0.02MM. Ensure that the air outlet is separated from the original material of the tuyere to achieve no condensation.


2. The setting of central air conditioning is also very important. On hot days, customers turn on the air conditioner when they arrive at home. They often want to set the temperature below 25 °C in one step. If the air conditioner installation company has set it in advance, the air conditioner will be below 25 °C even if it is on the first floor. A little cool, and then gradually cool down by yourself, so that the temperature of the air outlet panel is gradually reduced to adapt to the higher temperature in the room, so that the temperature of the panel of the air outlet will suddenly drop in one step, causing dew condensation. 


3. The installation of the central air-conditioning installation company is not in place. If the central air conditioner is not in place during installation, the connection of the four walls of the vent is not flat, and the water is not sealed, causing dripping, and other problems such as other problems are likely to occur. 


4. The drain pipe is defective. Drainage is not smooth due to aging relaxation or bending into a wavy shape. Or, the drain pipe leading out of the outdoor is blocked by humans or the drain port is blocked by the dirt, so that the dew condensation water cannot be discharged.



Send Inquiry